TXL02

RATINGS AND CHARACTERISTICS
Maximum Working Voltage 270V ac rms., 400V dc
Rated current See tables for TXL02--- range
Inductance See tables for TXL02--- range
DC Resistance See tables for TXL02--- range
Climatic category 25/105/56
Maximum temperature range Operating -25 to +105 °C
Storage -55 to +125 °C
Mass Size Q 30g max
Size R 50g max
Vibration Frequency sweep of 10Hz to 55Hz with 0.35mm displacement for 6 hours. IEC68-2-6 Test Fc Requirement: No visible damage, Inductance +/- 10%
Bump 1000 bumps of each 16ms with acceleration of 98m/s. IEC68-2-29 Test Eb Requirement: No visible damage, Inductance +/- 10%
Resistance to soldering heat Solder bath for 3s @ 350 °C, 6mm from body IEC68-2-20A Method 1B
Solderability Maximum soldering time, 2.5s @ 235 °C Solder globule test, IEC 68-2-20Ta
Robustness of terminations 1Kg (10N) IEC 68-2-21 Test Ua Tensile Requirement: No visible damage to the body. No deviation in nominal inductance and dc resistance
500g (5N) IEC 68-2-21 Test Ub Bending